Hi,
We had a power problem in enclosure 3 of our MSA2000 G3
After replacement of the power, we now have an issue with the SAS cannels
We see the following
Unhealthy Component
-------------------
Component ID: Enclosure 4, Expansion Module B, Out Expansion Port
Health: Degraded
Health Reason: The enclosure expansion port is degraded; some, but not all, of the PHY lanes can support activity.
Health Recommendation: - Check the SAS expansion cable between enclosures connected through the indicated port, and replace the cable if necessary.\n- If this does not correct the problem, check that the modules at each end of the cable are powered up and have good health; replace any faulty controller module or expansion module.
Unhealthy Component
-------------------
Component ID: Enclosure 3, Expansion Module A, In Expansion Port
Health: Degraded
Health Reason: The enclosure expansion port is degraded; some, but not all, of the PHY lanes can support activity.
Health Recommendation: - Check the SAS expansion cable between enclosures connected through the indicated port, and replace the cable if necessary.\n- If this does not correct the problem, check that the modules at each end of the cable are powered up and have good health; replace any faulty controller module or expansion module.
Unhealthy Component
-------------------
Component ID: Enclosure 3, Expansion Module B, In Expansion Port
Health: Degraded
Health Reason: The enclosure expansion port is degraded; some, but not all, of the PHY lanes can support activity.
Health Recommendation: - Check the SAS expansion cable between enclosures connected through the indicated port, and replace the cable if necessary.\n- If this does not correct the problem, check that the modules at each end of the cable are powered up and have good health; replace any faulty controller module or expansion module.
Unhealthy Component
-------------------
Component ID: Enclosure 2, Expansion Module A, Out Expansion Port
Health: Degraded
Health Reason: The enclosure expansion port is degraded; some, but not all, of the PHY lanes can support activity.
Health Recommendation: - Check the SAS expansion cable between enclosures connected through the indicated port, and replace the cable if necessary.\n- If this does not correct the problem, check that the modules at each end of the cable are powered up and have good health; replace any faulty controller module or expansion module.
So, on enclosure 3 both IN ports on the IOMS are 'faulty' and on enclosure 4 one SAS OUT port and on Enclosure one SAS OUT port (but on the other side). This would imply enclosure 3 cannot be properly reached, but the MSA seems to be working fine.
If we look further down on the log we see the following
U12-6G Degraded A subcomponent of this component is unhealthy. - No action is required. for enclosure 2, 3 and 4.
What could be causing this please. We have reseated the SAS cables