Re: HPE MSA 2050 Storage Capacity not refreshed in Server 2016 after removing...

Can you please help us to understand if the issue got resolved or not?If issue got resolved then how?Also request you to mark the forum as resolved if there is no more outstanding query from your end...

View Article


Re: MSA2050 - How to get a proper certificate from Microsoft CA

Can you please help us to understand if the issue got resolved or not?If issue got resolved then how?Also request you to mark the forum as resolved if there is no more outstanding query from your end...

View Article


Re: MSA 2050 - ICMP Drop and LUN Config

Can you please help us to understand if the issue got resolved or not?If issue got resolved then how?Also request you to mark the forum as resolved if there is no more outstanding query from your end...

View Article

Re: What are the required part numbers for upgrading an MSA 2040 to an MSA...

Can you please help us to understand if the issue got resolved or not?If issue got resolved then how?Also request you to mark the forum as resolved if there is no more outstanding query from your end...

View Article

Re: MSA 2040 disk spare failed

Hi,Firmware wersion is GL101R001.Total drive in system is 24.Vdisks in system is 3 -vd01, vd02, vd03.I verified and in vd02 not have hardware error any other drive.This solution with move some working...

View Article


Re: HPE MSA 2050 Storage Capacity not refreshed in Server 2016 after removing...

Mr.  Subhajit, thank you. As you suggested,1. backed up the data first2. remove entire disk group3. recreate disk group , volume , and mapping4. solvedHave a nice day.

View Article

Re: MSA 2040 disk spare failed

Yes you can move any spare drive from one location to other location and for that no downtime required. Our objective is to identify if any issue with slot 1.14 Hope this helps!RegardsSubhajitI am an...

View Article

Best RAID Setup for MSA 2050

Hi everyone,We need suggestion about RAID on MSA 2050currently we have 8 SAS x 900GB and we setup it as follow:7 SAS as RAID 5 and 1 SAS as Global Spare.is it safety? Some said RAID 5 was very...

View Article


Re: MSA 2040 disk spare failed

I moved spare disk from workin slot to 1.14. Disk filed after moving in slot 1.14 Second problem is that when I moved disk spare to his orginal slot he failed. How to reset disk to factory reset and...

View Article


Image may be NSFW.
Clik here to view.

Re: MSA 2040 disk spare failed

At this point it looks like slot 1.14 is bad for which you may have to replace the Chassis.If the drive back to it's original slot and shows as failed then only option is to physically re-seat the...

View Article

Re: Best RAID Setup for MSA 2050

 RAID you need to configure based on your requirement and capacity to afford this. MSA2050 supports RAID 1, 5, 6 and 10Now RAID 1 and 5  VDG both can sustain upto one drive failure. In case of RAID 6...

View Article

Re: MSA 2040 disk spare failed

How to re-seat the drive to get proper state of the drive.?In another system disk works, is ok.If I replace the chassis the configuration array will be lost? I have two controllers.

View Article

SAS problem MSA2000 G3

Hi,We had a power problem in enclosure 3 of our MSA2000 G3After replacement of the power, we now have an issue with the SAS cannelsWe see the followingUnhealthy Component-------------------Component...

View Article


Re: MSA 2040 disk spare failed

You just have to physically remove the drive from the slot. Half of the slot or bay is enough. Give 1min and then put it back.Then check in CLI and SMU about the state of the drive.As you have...

View Article

Re: MSA 2040 disk spare failed

Hello,If the disk works in another system then there are a couple of steps you can take.Both your array and your drives need upgrading. There are several drive types that have a critical firmware...

View Article


Re: SAS problem MSA2000 G3

Hello,Due to the power issue you may have either caused the backend SAS map to be rebuilt or incorrectly scanned. There are a couple of things you can try.Check and verify the cables are correctly...

View Article

Expand 2-tier, one pool MSA 2052

Hi.Need to add more disk for more preformance to our MSA 2052.Current setup: 2-tier, 1 pool only (A)6 800GB SSD RAID6 (no spare) (HPE MSA 2052 SAN Dual Controller SFF Storage)10 4TB MDL RAID6 + 2 spare...

View Article


Re: MSA 2040 disk spare failed

Hi, Remove drive from the slot and wait 1 min and put in back nothing change. Disk still failed. In MSU state drive is failed.

View Article

Re: SAS problem MSA2000 G3

gehter with HPE we isolated the problemOn two IO Modules we found a SAS channel being disabled due to internal errors, so instead of 4 active channels per port there were only 3. One module had an...

View Article

HP MSA 2050 remove disk group and vdrain

Hello!I have 3 disk groups on my MSA 2050 and going to remove 1 group. I do it by the way that described in manual and VDRAIN process starts. So, all data from removing disk group not going to be...