To properly shut down an HP MSA 2062 for relocation, it's important to follow the recommended procedure to ensure data integrity and avoid hardware damage. Here's a step-by-step guide to safely shutting down your HP MSA 2062:

Step-by-Step Shutdown Procedure:
  1. Notify Users:

    • Inform all users and applications connected to the storage system of the planned shutdown to prevent data loss and ensure all processes are stopped.
  2. Stop I/O Operations:

    • Ensure all I/O operations to the MSA 2062 are stopped. This can be done by shutting down or disconnecting the servers or applications using the storage.
  3. Access the Management Interface:

    • Log in to the SMU (Storage Management Utility) or use the CLI (Command Line Interface) to manage the MSA 2062.
  4. Check System Status:

    • Verify that the system is in a healthy state. Resolve any critical alerts or issues before proceeding with the shutdown.
  5. Graceful Shutdown (Using SMU):

    • Navigate to the "System" tab.
    • Select "Shutdown or Restart".
    • Choose "Shutdown" and confirm. This will safely power down the storage system.

    Graceful Shutdown (Using CLI):

    • Log in to the CLI.
    • Execute the following command to initiate a graceful shutdown:
      arduino
      Copy code
      shutdown both
    • Confirm the shutdown command when prompted.
  6. Wait for Complete Shutdown:

    • Ensure that the system has completely shut down. All LEDs on the front panel should turn off or indicate the system is powered down.
  7. Power Off the Enclosures:

    • Turn off power to the disk enclosures by pressing the power buttons on the power supply units.
  8. Disconnect Power Cables:

    • Unplug the power cables from the power supply units to ensure no power is reaching the device.
  9. Label and Disconnect Cables:

    • Label and disconnect all network and data cables to avoid confusion during reinstallation.
  10. Prepare for Transport:

    • Ensure the MSA 2062 and its components are securely packed to prevent damage during the move.
Additional Considerations:
  • Backup Data:

    • Before shutting down, ensure you have a complete backup of your data.
  • Documentation:

    • Document the current configuration and connections to facilitate reinstallation at the new location.

By following these steps, you can ensure a safe and proper shutdown of your HP MSA 2062, minimizing the risk of data loss or hardware damage during the move.

 

Source:

Here are the direct URLs to the HPE documentation for the MSA 2062:

1. HPE MSA 2060/2062 User Guide:
- (https://support.hpe.com/hpesc/public/docDisplay?docId=a00095525en_us)

2. HPE MSA 2060/2062 SMU Reference Guide:
- (https://support.hpe.com/hpesc/public/docDisplay?docId=a00095526en_us)

3. HPE MSA Storage CLI Reference Guide:
- (https://support.hpe.com/hpesc/public/docDisplay?docId=a00095527en_us)

 

Viewing all articles
Browse latest Browse all 8343

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>