Re: MSA 2050 linear config

$
0
0

Hi,

From 5th generation on MSA's does not support linear configurations anymore, only virtual pools...

So if  you want to use 2 types of disks (SAS and SSD in your case) you will need to have the advanced data services license. Or use just 1 type of drives...

Kr,

Bart


Re: MSA 2050 linear config

$
0
0

Please refer the SMU guide (page no 20), it's clearly mentioned "If you have the Performance Tier license, you can use SSDs for virtual disk groups."

https://support.hpe.com/hpsc/doc/public/display?docId=a00017707en_us

 

Also you can check best practice whitepaper (page no 5), it's clearly mentioned "A license is required for the Performance Tier for mixed SSD and HDD systems. For a system with only SSDs, the Performance Tier license is not required."

https://h20195.www2.hpe.com/v2/getdocument.aspx?docname=a00015961enw

 

So this is the reason you are not able to create VDG with SSDs

 

Hope this helps!
Regards
Subhajit

If you feel this was helpful please click the KUDOS! thumb below!

***********************************************************************************

DL360pG8 with P431 and MSA 1050 SAS

$
0
0

Hi,

my receller said to me to buy a P431 controller to connect my DL360P G8 with my MSA 1050 SAS. On the  MSA 1050 i see the link is ok with controller, the connector led is on, the initiator is mapped with volumes. Everything looks ok  but the P431 doesn't see anything.

I use VMWare 6.7 and modify with ssacli the P431 to enable HBA mode but no more success.

My MSA 1050 works fine with another server DL360 G9 with H241 controller

An idea ? Thank's

Re: MSA 2050 linear config

$
0
0

Hi!

Thanks a lot for your responses. 

Now, everything it´s clear. 

Thanks!

Re: MSA 2050 linear config

$
0
0

..............Nice to hear that provided information helped you. Requesting you to provide Kudos to help me as well.....:)

 

Hope this helps!
Regards
Subhajit

If you feel this was helpful please click the KUDOS! thumb below!

***********************************************************************************

Re: DL360pG8 with P431 and MSA 1050 SAS

$
0
0

1st of all VmWare 6.7 not yet tested with MSA1050 so this is not a supported environment.

Next thing I have checked HPE MSA1050 Compatibility with VmWare 6.5 and I don't see P431 supported but H241 supported. Please find the link to get details,

https://h20272.www2.hpe.com/SPOCK/Content/ExportPDFView.aspx?Id=95096&typeId=2

 

Note: In order to access HPE SPOCK you need HPE Passport login

 

Hope this helps!
Regards
Subhajit

If you feel this was helpful please click the KUDOS! thumb below!

***********************************************************************************

Storage Discussion

$
0
0

Do the model HPE MSA 2050 compatible with D3600 base enclosure ??

 

Storage Discussion!

$
0
0

Do the Model HPE MSA 2050 support D 3600 Base enclosure??


Re: DL360pG8 with P431 and MSA 1050 SAS

$
0
0

My DL360 Gen9 running vmware 6.7 and connected on MSA 1050 works fine.

I think my resseler is in fault giving me a P431 to connect my DL360 Gen8

Re: DL360pG8 with P431 and MSA 1050 SAS

$
0
0

Yes as I have mentioned earlier your DL360 Gen9 using H241 HBA which is actually supported with MSA 1050 so this is working fine.

But in case of DL260 Gen8 you are using P431 which is actually not supported with MSA 1050 as per the HPE SPOCK so this could be the reason that this is not working

I would suggest to refer the HPE SPOCK link which I have given and identify any supported HBA and use it in DL360 Gen8 server

 

Hope this helps!
Regards
Subhajit

If you feel this was helpful please click the KUDOS! thumb below!

***********************************************************************************

Re: Storage Discussion!

$
0
0

Hi,

If I remember well is the D3600 supported on the previous generation MSA2040 but not on the MSA2050.

These are the 2 drive enclosures supported on MSA2050:

HPE MSA 2050 LFF Disk Enclosure   Q1J06A

HPE MSA 2050 SFF Disk Enclosure   Q1J07A

 

Kr,

Bart

Trouble Removing a d2600 disk enclosure from SA p812

$
0
0

I have a Proliant dl180 G6 with a P812 Smart Controller showing 4 logical devices, running Windows 2008 R2. I have three HP Storagework D2600 disk Enclosures attached to it. 

Enclosure A) 12 x 2TB SATA Drives

Enclosure B) 12 x 2TB SATA Drives

Enclosure C) 12 x 2TB SAS Drives

I would like to decommission enclosure B. You'd think it would be a simple matter. I've decommisioned enclosures on other servers without a problem. On this server I'm getting a strange result. When I remove enclosure B from service and bring up the server, the controller, it shows 0 logical drives instead of 3 logical drives. If I go back to the original setup, I get 4 logical drives. When I leave the enclosure B connected and disconnected another enclosure (as a test), the controller shows 0 logical drives. None of the logical drives have anything shared between them (ie. hot spare drives). Why is this happening? How can I fix this? I don't want to screw up the other two enclosures. Thanks, in advance.

 

Kevin

Re: Trouble Removing a d2600 disk enclosure from SA p812

$
0
0

Hello,

Couple of questions for you on your configuration from the host side. Do you have MPIO installed correctly? Do you have two paths to the enclosures? Straight thru or redudant cabling? Have you unmapped the LUN/volume on the D2600 you are trying to decommission?

From your description it sounds like you have a software host side issue where the LUNs are interconnected. Did you use the SSA to configure the LUNs or a host based software solution?

However, there is not enough information here to determine your current configuration with all three enclosures connected. You mention there are 4 LUNs yet three enclosures. This inidcates you have at least one enclosure that either has 2 LUNs or you have one LUN that exists across two enclosures.  With SATA HDDs in the first two enclosures are you sure you do not have one LUN spanning those two enclosures?

I would urge a backup of your important data before proceeding further.  One consideration is to perform the backup delete all the LUNs, remove the enclosure and then you can recreate the LUNs according to your new plans. I understand that is a lot of work but would leave you with a fresh install and remove any issues.

Cheers,

Shawn

Re: Storage Discussion!

$
0
0

Hello,

The MSA2050 supports the MSA2050 JBOD enclosure. Only in an upgrade scenario is the MSA2040 or D2700 enclosure.

 

The D3600 and D3700 enclosures have never been supported on any MSA array. Please refer to SPOCK for current supported configurations: https://h20272.www2.hpe.com/spock/

Cheers,
Shawn

Re: Trouble Removing a d2600 disk enclosure from SA p812

$
0
0

HPE Smart Storage Administrator

Controller Hardware Information

  • Controller Smart Array P812 Slot 0 PCI Address (Domain:Bus:Device.Function) 0000:04:00.0 Hardware Revision C Controller Serial Number PAGXQ0BRH2K23Z Firmware Version 6.64 Number of Ports 6 (2 Internal / 4 External) Controller Memory Module Size 1024 MiB Battery/Capacitor Pack Count 1
  • Controller Settings
    Transformation Priority High Rebuild Priority High Surface Scan Analysis Priority High Surface Scan Delay Not Applicable Parallel Surface Scan Supported No Physical Drive Write Cache State Enabled
  • Advanced Controller Settings
    RAID 5/6/50/60 Degraded Mode Performance Optimization Enabled Physical Drive Request Elevator Sort Enabled RAID 6/60 Alternate Inconsistency Repair Policy Disabled Maximum Drive Request Queue Depth Automatic Monitor and Performance Analysis Delay 60 min
  • Controller Configuration Summary
    Arrays 4 SmartCache Arrays 0 Logical Drives 4 Data Logical Drives 4 SmartCache for Logical Drives 0 Physical Drives 61 Data Drives 46 SmartCache Drives 0 Spare Drives 3 Drives in HBA Mode 0 Unassigned Drives 12 Primary Boot Logical Drive/Volume None Secondary Boot Logical Drive/Volume None
  • Port Settings
    Port 5I   Port Location Internal Port 6I   Port Location Internal Port 1E   Port Location External Port 2E   Port Location External Port 3E   Port Location External Port 4E   Port Location External
  • Controller Status
    Controller Status OK Cache Status OK Battery/Capacitor Status OK
  • Storage Enclosures
    DL18x25SFF
    D2600 SAS AJ832A
    StorageWorks D2600
    StorageWorks D2600

Each array is connected to its own port on the p812. 

Array Details

  • Status OK Used Space 20.0 TiB (100.0%) Total Usable Space 20.0 TiB Spare Drive Type Dedicated Spare Drives. Drives designated as spares can only be used as spare drives.
  • Logical Drives
    Logical Drive 3 18.19 TiB (20.00 TB)
  • Physical Drives
    2 TB SAS HDD at Port 1E : Box 1 : Bay 2
    2 TB SAS HDD at Port 1E : Box 1 : Bay 3
    2 TB SAS HDD at Port 1E : Box 1 : Bay 4
    2 TB SAS HDD at Port 1E : Box 1 : Bay 5
    2 TB SAS HDD at Port 1E : Box 1 : Bay 6
    2 TB SAS HDD at Port 1E : Box 1 : Bay 7
    2 TB SAS HDD at Port 1E : Box 1 : Bay 8
    2 TB SAS HDD at Port 1E : Box 1 : Bay 9
    2 TB SAS HDD at Port 1E : Box 1 : Bay 10
    2 TB SAS HDD at Port 1E : Box 1 : Bay 11
    2 TB SAS HDD at Port 1E : Box 1 : Bay 12
  • Spare Drives
    2 TB SAS HDD at Port 1E : Box 1 : Bay 1 (Spare)
  •  
    Array Details
    Status OK Used Space 6146.0 GiB (100.0%) Total Usable Space 6.0 TiB Spare Drive Type Dedicated Spare Drives. Drives designated as spares can only be used as spare drives.
  • Logical Drives
    Logical Drive 5 5.73 TiB (6.30 TB)
  • Physical Drives
    300 GB SAS HDD at Port 5I : Box 1 : Bay 3
    300 GB SAS HDD at Port 5I : Box 1 : Bay 4
    300 GB SAS HDD at Port 5I : Box 1 : Bay 5
    300 GB SAS HDD at Port 5I : Box 1 : Bay 6
    300 GB SAS HDD at Port 5I : Box 1 : Bay 7
    300 GB SAS HDD at Port 5I : Box 1 : Bay 8
    300 GB SAS HDD at Port 5I : Box 1 : Bay 9
    300 GB SAS HDD at Port 5I : Box 1 : Bay 10
    300 GB SAS HDD at Port 5I : Box 1 : Bay 11
    300 GB SAS HDD at Port 5I : Box 1 : Bay 12
    300 GB SAS HDD at Port 5I : Box 1 : Bay 13
    300 GB SAS HDD at Port 5I : Box 1 : Bay 14
    300 GB SAS HDD at Port 5I : Box 1 : Bay 15
    300 GB SAS HDD at Port 5I : Box 1 : Bay 16
    300 GB SAS HDD at Port 5I : Box 1 : Bay 17
    300 GB SAS HDD at Port 5I : Box 1 : Bay 18
    300 GB SAS HDD at Port 5I : Box 1 : Bay 19
    300 GB SAS HDD at Port 5I : Box 1 : Bay 20
    300 GB SAS HDD at Port 5I : Box 1 : Bay 21
    300 GB SAS HDD at Port 5I : Box 1 : Bay 22
    300 GB SAS HDD at Port 5I : Box 1 : Bay 23
    300 GB SAS HDD at Port 5I : Box 1 : Bay 24
  • Spare Drives
    300 GB SAS HDD at Port 5I : Box 1 : Bay 25 (Spare)
  • Device Path
    Smart Array P812 in Embedded Slot
     
     

HPE Smart Storage Administrator

  • Array Details
    Status OK Used Space 20.0 TiB (100.0%) Total Usable Space 20.0 TiB Spare Drive Type Dedicated Spare Drives. Drives designated as spares can only be used as spare drives.
  • Logical Drives
    Logical Drive 6
    18.19 TiB (20.00 TB)
  • Physical Drives
    2 TB SATA HDD at Port 2E : Box 1 : Bay 2
    2 TB SATA HDD at Port 2E : Box 1 : Bay 3
    2 TB SATA HDD at Port 2E : Box 1 : Bay 4
    2 TB SATA HDD at Port 2E : Box 1 : Bay 5
    2 TB SATA HDD at Port 2E : Box 1 : Bay 6
    2 TB SATA HDD at Port 2E : Box 1 : Bay 7
    2 TB SATA HDD at Port 2E : Box 1 : Bay 8
    2 TB SATA HDD at Port 2E : Box 1 : Bay 9
    2 TB SATA HDD at Port 2E : Box 1 : Bay 10
    2 TB SATA HDD at Port 2E : Box 1 : Bay 11
    2 TB SATA HDD at Port 2E : Box 1 : Bay 12
  • Spare Drives
    2 TB SATA HDD at Port 4E : Box 1 : Bay 12 (Spare)
  •  
    Note: This is the array I want to remove. there are no logical drives.
    D2600 SAS AJ832A at Port 4E : Box 1
    SATA HDD  2 TB Bay 1
     SATA HDD 2 TB Bay 2
     SATA HDD 2 TB Bay 3
     SATA HDD 2 TB Bay 4
     SATA HDD 2 TB Bay 5
     SATA HDD 2 TB Bay 6
     SATA HDD 2 TB Bay 7
     SATA HDD 2 TB Bay 8
     SATA HDD 2 TB Bay 9
     SATA HDD 2 TB Bay 10
     SATA HDD 2 TB Bay 11

MSA 2040 SAS connectivity WORKS 6 GB\s no 12 GB\s

$
0
0

Hi, I have a HP MSA 2040 with a SAS connection on HP DL380 G9 servers running Windows Server 2016 Datacenter and the connectivity between the Windows server and the MSA 2040 is only 6 GB \ s while it should be 12 GB \ s. The two controllers on the MSA 2040 are 12 GB \ s and the 8644 12 GB \ s. On the servers I have HP h241 HBA 12 GB \ s cards. But it only works for 6 GB \ s.

Re: New MSA Storage Web Page for MSA Firmware and Release Notes

$
0
0

Thanks.

It seems not to work with firefox only with chrome.

Re: New MSA Storage Web Page for MSA Firmware and Release Notes

$
0
0

>It seems not to work with firefox only with chrome.

My firefox had a comment about clearing the browser cache.  ??

New MSA 2050/2052/1050 Controller Firmware

$
0
0

Announcing New MSA 2050/2052/1050 Controller firmware!!!

Yesterday we published new controller firmware for the MSA 2050/2052/1050. The new firmware and release notes are now available on the MSA Firmware site (www.hpe.com/storage/MSAFirmware).

VL270R001-01 (MSA 2050/2052)
VE270R001-01 (MSA 1050) 

 

MSA 2040 SAS connectivity WORKS 6 GB\s no 12 GB\s

$
0
0

Hi, I have a HP MSA 2040 with a SAS connection on HP DL380 G9 servers running Windows Server 2016 Datacenter and the connectivity between the Windows server and the MSA 2040 is only 6 GB \ s while it should be 12 GB \ s. The two controllers on the MSA 2040 are 12 GB \ s and the 8644 12 GB \ s. On the servers I have HP h241 HBA 12 GB \ s cards. But it only works for 6 GB \ s.