Quantcast
Browsing all 8325 articles
Browse latest View live

Re: MSA P2000 G3 replace failed controller -cant shutdown the failed...

 Is Controller A physically dead controller ? no power taking ?I would suggest to connect Controller B with serial cable and check everything before you proceed further. Few commands to check,show...

View Article


Re: MSA P2000 G3 replace failed controller -cant shutdown the failed...

Hello Luke,It is a little hard to tell what state the controllers are in from the limited output. If you are connected to controller A and gathering output it may not be responding enough to...

View Article


Re: MSA1050 - Delete Disk Group

Thanks for the reply.With a total of 13 disks I cannot create VDGs with the same number of disks even if I use the same RAID level. I don't have the license that enables tiering.How does MSA deal with...

View Article

Re: MSA 2040 Can't create new disk group

Thank you very much! This worked.I removed both read caches and then I could create the new disk group. After that I created the read caches again without a problem. I have just one more question. The...

View Article

Re: MSA 2040 Can't create new disk group

Hi,I'm glad I could helpFrom SMU guide:https://support.hpe.com/hpesc/public/docDisplay?docId=c04220794The system-level Vdisk Scrub option automatically checks all vdisks for disk defects. Scrub...

View Article


Re: MSA 2040 Can't create new disk group

Thank you so much for the help!I can now continue the the data migration in peace.

View Article

Re: MSA P2000 G3 replace failed controller -cant shutdown the failed...

Hello.there is an Amber led on Controller A  other lights are on.the unhealthy components of controller A (connected):Unhealthy Component  -------------------  Component ID: Enclosure 1, Controller A,...

View Article

Re: Implementation of a replication method between MSA 2050 and MSA 1050

Hello all,According to my tests, I think use snapshots.The idea is to take a snapshot regularly and map/mount the snapshot on the hosts (Windows Server) if you need to recover a backup (.What do you...

View Article


Re: MSA2050

so sorry for long time ti replayi made two poolpool A raid 10Pooll B Raid 5and one hdd as sparethe question:1: if one of controller fail does the second will take care of both pool2: the spare disk...

View Article


Re: Implementation of a replication method between MSA 2050 and MSA 1050

Hi all,So, I'm going to create 1 pool with all disks and 1 volume.This volume will be smaller than the pool. The free space will be for the snapshots.Then, I will execute this command (the options will...

View Article

Re: MSA2050

 To answer your questions,1: if one of controller fail does the second will take care of both pool>> Yes if one controller fail then other controller will take care of the VDGs part of failed...

View Article

Re: Implementation of a replication method between MSA 2050 and MSA 1050

 It's not clear what is your query actually. However trying to answer,So, I'm going to create 1 pool with all disks and 1 volume.>> There is nothing to comment here as it will be as per your...

View Article

Re: MSA2050

You mean that when I configure the spare disk I must tell the system which pool or VDG the separate dive belong to??

View Article


Re: MSA2050

 No I am saying you need to configure the drive as spare for the entire MSA. It's not specific for any Pool or VDG because in Virtual  Array there is no concept of dedicated spare. We have only Global...

View Article

Re: Implementation of a replication method between MSA 2050 and MSA 1050

Hi, >> It's not clear what is your query actually. However trying to answerOK, since replication is not possible, the project evolved. I would like just to have a daily backup. The idea is to...

View Article


Re: MSA2050

Hellosorry for more question......i make 2 pools A&BI make virtual volumes with Affinity (performance) for VM: (oracle-php-exchane)and with Affinity (Archive) for (file sharing....etc)does that...

View Article

HP MSA 2052

Hi, I'm planning on setting up a HP 2052 with automatic tiering enabled. I have a couple of question I hope someone could answer: 1) Using two SSD drive in RAID1 for the performance tier, if a single...

View Article


Re: HP MSA 2052

 Please find the answers,1) Using two SSD drive in RAID1 for the performance tier, if a single SSD fails and the Health  of the disk group effected would the SAN disable this as a performance Tier and...

View Article

Re: HP MSA 2052

Hi SUBHAJIT KHANBARMAN, Thank you very much for your response,  Best regards Neil

View Article

Re: MSA2050

 Yes if you are looking for Performance for your volumes then at the time of VV creation you can select affinity feature as Performance.Please note affinity feature doesn't mean volume pinning which...

View Article
Browsing all 8325 articles