Re: Critical Firmware Upgrade Required For Certain MSA SAS Solid State Drive...

Good day MSA Community!Last week a new version of MSA Health Check was released - Version 1.2.0.  Version 1.2.0 is introducing a new SSD Critical Alert feature to the MSA Storage Health Check...

View Article


Re: New HPE Tool - MSA Health Check

Good day MSA Community!Last week a new version of MSA Health Check was released - Version 1.2.0.  Version 1.2.0 is introducing a new SSD Critical Alert feature to the MSA Storage Health Check...

View Article


MSA2040 installing new disks

We have a MSA2040 with 14 disks installed at the moment. We need to expand with more storage and have purchased 4x new drives which will be a new raid.The SAN hasn't been updated since sometimes in...

View Article

Re: MSA2040 installing new disks

HiThe short answer is no you don't have to upgrade firmware and MSA can tolarate different firmwareversions.it is a good idea to upgrade firmware thought updating disk firmware is an off-line proccess...

View Article

Re: Implementation of a replication method between MSA 2050 and MSA 1050

Hello,Sorry for the late response, I needed to think about.You indicated :1st of all you can't connect MSA 2050 and MSA 1050 with SAS interface and use it as a single unit. You need to use both systems...

View Article


Re: Implementation of a replication method between MSA 2050 and MSA 1050

 As per my understanding discussion started with two systems as per this statement "Implementation of a replication method between MSA 2050 and MSA 1050" -> This means MSA 2050 one controller...

View Article

Re: MSA2040 installing new disks

If I want to upgrade my disks firmware and need to put it offilne, is there a way of putting the arrays offline from the MSA, does the upgrade process put the arrays offline automatically before...

View Article

Expand virtual volume - free pool / disk group space - MSA 1050

Hi all,I've been searching for an answer here and there but didn't find a question close enough to my problem and poor understanding of the subject.I am looking to expand a virtual volume fromt about...

View Article


Re: Implementation of a replication method between MSA 2050 and MSA 1050

Yes, exactly. MSA 1050 controller enclosure and MSA 2050 drive enclosure.I’m so sorry, for this confusion. I wish I could have posted a photo to clarify the situation.Currently, the cabling is...

View Article


Re: Implementation of a replication method between MSA 2050 and MSA 1050

Hello,Your configuration is NOT supported!Currently, the cabling is (connection at the back-end of the enclosures) :Port SAS 1 - controller A - MSA 1050 connected to HPE H241 Smart HBA cardPort SAS 1 -...

View Article

Re: MSA2040 installing new disks

Hello,You should stop all host IO during a drive firmware upgrade. That should be done from the host(s). You can place a volume on the array in a stopped state, but this should not be done with active...

View Article

Image may be NSFW.
Clik here to view.

Re: Implementation of a replication method between MSA 2050 and MSA 1050

Hello,I already read the MSA1050 Cabling Guide.I thought that my cabling was correct but I was wrong. Nevertheless, page 8 is the cabling that I've done. I think there's been a mix-up from the...

View Article

Re: Expand virtual volume - free pool / disk group space - MSA 1050

 It's very difficult to explain things without watching the problem properly. Let me give a try.There is something called physical space capacity limit and logical space capacity limit.First you need...

View Article


Re: Implementation of a replication method between MSA 2050 and MSA 1050

Hello,Sometimes a picture is worth a thousand words. You actually have an MSA1050 array enclosure connected to an MSA Gen5 JBOD enclosure (not an MSA2050 array). Your cabling configuration is...

View Article

Re: MSA2040 installing new disks

Thank you for your reply. I just upgraded the controller firmware and now I'm going to plan downtime to upgrade the disk firmware before I install the new disks.

View Article


MSA 2052 & Vsphere 6.7 - discrepancy free space

Hi Community,I'm looking at the available storage capacity in Vsphere and comparing it with the actually used space on the MSA 2052 Pool.The whole Pool of the MSA is used as a VMFS6 volume by...

View Article

Re: MSA 2052 & Vsphere 6.7 - discrepancy free space

 You need to provide more details like what is the total size of the MSA Volume, how much is showing as used space out of it? Also good to know Pool level space details from where this MSA volume...

View Article


New MSA 1050/205x Firmware released today - VE270P004 and VL270P004

Good day everyone!  Today HPE released a new firmware update for the MSA 1050, 2050, and 2052.  There are some new enhancements as well as issues fixed.  It is recommended that you upgrade to this new...

View Article

Re: New MSA 1050/205x Firmware released today - VE270P004 and VL270P004

Hello  ,Thanks a lot for sharing the new released firmware update for the MSA 1050, 2050, and 2052.    

View Article

Re: MSA 2052 & Vsphere 6.7 - discrepancy free space

If I log into MSA 2050 I see this Under Home:CapacityLogical:                                                                            Reserved:3175GiB Allocated: 4462GiB Unallocated:...