Re: MSA 1040 - Adding disks to RAID10 Linear pool

I understand you have linear vdisk configured in RAID10 and you want to expand this with 5 more disks.My suggestion would be not to try this because once vdisk expansion started then you can't stop it...

View Article


Re: MSA 1040 - Adding disks to RAID10 Linear pool

Thank you for the information. I forgot to provide some details - 1.2TB 15K drives are in the system - Currently 6 of them with 1 spare in RAID10.  System is very full, though not often at high...

View Article


Re: MSA 1040 - Adding disks to RAID10 Linear pool

If you are aware of the consequences of vdisk expansion and you don't have option but to go for vdisk expansion only then you can refer same best practice guide and page no 40 having the table which...

View Article

Re: MSA P2000 iSCSI volume is not initialized (not in the VMWare, not in...

Solution is to log in to console of p2000, then type:show unwritable-cacheIf percent > 0 then run:clear cacheIt helps for me

View Article

Re: P2000 G3: adding a new disk as spare fails

The problem is solved now.After a complete restart of the Storage (all controllers and all attached boxes), the VDisk acceoted the new Spare Disk without any error. Thanks all for their replies. kind...

View Article


Can't move master volume to standard volume in MSA -2040

Hi All, I have created snapshot from a linear volume as per customer demand..  It's automatically created snap-pool which consumed space from disk-pool.Finally I have deleted   snapshot.  But when I...

View Article

Re: Can't move master volume to standard volume in MSA -2040

Try below commands,# show master-volumes# show snapshots master-volume <master_volume_name># delete snapshot force <snapshot_name># convert master-to-std <Volume_name># delete...

View Article

MSA2050 unable to add disk group

Hello,I'm unable to create a new ssd diskgroup, i get the followinf error message :"a performance tier cannot be added to a virtual pool that contains a read cache"i have currently 4 diskgroups:1 dga01...

View Article


Re: MSA2050 unable to add disk group

You can't have Performance Tier and read cache in same Pool. You can have either Performance tier or read cache.This is as per design.So you can delete read cache for one Pool and create new VDG with...

View Article


Re: MSA2050 unable to add disk group

Thank's SubhajitIs it possible to juste delete the read cache SSD diskgroup without impact (other than performance) of the working system?if yes , i will delete the read cache diskgroup in one pool,...

View Article

Re: MSA2050 unable to add disk group

Yes you can delete read cahe anytime.No impact to production. Even if there is any data in read cache doesn't matter at all because actual data will be at the drive. Please note this is only help for...

View Article

Re: MSA2050 unable to add disk group

I see , so there is no way to dedicate a new volume to the new SSD's

View Article

Re: MSA2050 unable to add disk group

if create a new volume in the pool with a different type of disk group (SSD and SAS), this volume will automaticaticaly spread across the different disk groups ? no way to limit the volume on the SSD's ?

View Article


Re: MSA2050 unable to add disk group

No that's not possible because MSA 2050 fully virtualized array.Earlier we had concept of linear array where dedicated vdisk concept was there which got created with dedicated drives. Later we used to...

View Article

Re: MSA2050 unable to add disk group

I'm very happy with your quick and clear answers Subhajit.many thank'sGérard

View Article


Re: Can't move master volume to standard volume in MSA -2040

Hi Subhajit,Thanks for your valuable info.My issue is solved now.  

View Article

MSA 1050, 2050, and 2052 Storage Systems - Storage Controller Firmware...

This post announces the release of controller firmware VE270P003-01 for HPE MSA 1050 Storage systems and VL270P003-01 for HPE MSA 2050 and 2052 Storage systems.This is a general availability (GA) patch...

View Article


Only LUN0 visible on Server(s)

Hi All,We have purchased 2 x DL380 40 core servers both with HPE E208e-P SR dual port 12gbps SAS controllers.We purchased an Infortrend GSa2024RT SAN with dual 12Gbps SAS controllers.Currently I've got...

View Article

Re: MSA2050 unable to add disk group

One more question Subhajit if you read this :is there a way to move disk groups between pool's ( without remove/recreate ...) thank'sGérard

View Article

Re: MSA2050 unable to add disk group

Virtual DIsk Group can't move from one Pool to another Pool.There is one option called Volume Copy feature where it can copy volume from one Pool to another Pool. You can check this option. Hope this...

View Article