Re: MSA P2000 G3 replace failed controller -cant shutdown the failed controller from the SMU

$
0
0

Hi Luke,

It does not seem to capture the reason for controller B reporting degraded status.

I would recommend to first fix controller B issues before replacing controller A.

Restarting storage controller B after scheduling a down time would be a good idea if its a false alert.

Share the output of the following commands:

show cache-parameters

show vdisks

show ports

Confirm whether the show network-parameters output indicates health status

Have you already tried restarting storage controller A and removing/reseating it?

It would be good if you can engage HPE support team through chat option to review the logs and provide the recommendations. I believe that basic support would be available even for out of warranty units.