Hello,
Looks like the Vdisk is on Raid 5?
Have you assigned the other two spare as global spare?
If not, please do
- In the Configuration View panel, right-click the system and select Provisioning > Manage Global Spares. The main panel shows information about available disks in the system. Existing spares are labeled GLOBAL SP
- In the Disk Sets table, the number of white slots in the Disks field shows how many spares you can add.
- In the enclosure view or list, only existing global spares and suitable available disks are selectable.
- Select spares to remove, disks to add as spares, or both.
- Click Modify Spares. If the task succeeds, the panel is updated to show which disks are now global spares.
Once the rebuild is complete, replace the faulty drive.
Get back to me with Logs if you need further assistance.
Tools > Save logs
-JD