Hi,
Thank-you for your help, without this I would have been completely stuck
I ran a vdisk verify overnight, and as suspected it has shown errors on disk 8 & 11 :
An error was detected by a disk drive. (disk: channel: 0, ID: 7, SN: 6XR1xxxxxxxxxxxxx, enclosure: 1, slot: 8)(Key,Code,Qual:0x1,0x17,0x1)(CDB:Rd 03bf6280 0040)(Info:0x03BF629A)(CmdSpc:0x11201100, FRU:0x0, SnsKeySpc:0x800001)(Recovered Error, recovered data with retries)
An error was detected by a disk drive. (disk: channel: 0, ID: 10, SN: 6XR1MAKxxxxxxxx, enclosure: 1, slot: 11)(Key,Code,Qual:0x1,0x17,0x1)(CDB:Rd 00239e80 0040)(Info:0x00239EBC)(CmdSpc:0x11201100, FRU:0x0, SnsKeySpc:0x800001)(Recovered Error, recovered data with retries
The RAID is still in a healthy state - whats the best way to replace the drives?
- Pull them out one at a time - and rebuild with the dedicated spare?
- Wait until drive failure, and raid is "degraded state" - then rebuild with spare - this is more risky I think, just in case I get more than 2 drives fail again.
Thanks