Re: MSA 2040 disk spare failed

Hi,

Firmware wersion is GL101R001.

Total drive in system is 24.

Vdisks in system is 3 -vd01, vd02, vd03.

I verified and in vd02 not have hardware error any other drive.

This solution with move some working drive for me is very difficult and risk. The vdisk from which the disk move to 1.14 will may be damaged.
In vd01 I have one disk spare and this working spare maybe move to vd02 to 1.14.
What do you think about it?
Can such a test be done on a running MSA or do I have to shut down MSA?