What is Controller firmware version running ?
How many total drive present in this system?
How many vdisks present in this system?
Did you verified if any other drive part of same vdisk vd02 having hardware errors ? It's possible that other drive having issue not allowing reconstruction to get start or getting completed for 1.14 and due to that drive at location 1.14 getting failed again and again.
Other possibility would be issue with the slot itself.
If you have multiple vdisk then you can take downtime, stop host IO and then shutdown the system. Then move some working drive which is already part of some other vdisk like vd01 to slot 1.14 or in other words swap the location of the drive. Then start the MSA again and check after movement if this drive can sustain in 1.14 location or not. If not then issue with the slot for which you need to replace the entire chassis. If after movement drive got sustained and not failed then you need to troubleshoot vd02 and figure out if any other drive having issue or not.
Hope this helps!
Regards
Subhajit
I am an HPE employee
If you feel this was helpful please click the KUDOS! thumb below!
**********************************************************************