HPE Smart Storage Administrator
Controller Hardware Information
- Controller Smart Array P812 Slot 0 PCI Address (Domain:Bus:Device.Function) 0000:04:00.0 Hardware Revision C Controller Serial Number PAGXQ0BRH2K23Z Firmware Version 6.64 Number of Ports 6 (2 Internal / 4 External) Controller Memory Module Size 1024 MiB Battery/Capacitor Pack Count 1
- Controller SettingsTransformation Priority High Rebuild Priority High Surface Scan Analysis Priority High Surface Scan Delay Not Applicable Parallel Surface Scan Supported No Physical Drive Write Cache State Enabled
- Advanced Controller SettingsRAID 5/6/50/60 Degraded Mode Performance Optimization Enabled Physical Drive Request Elevator Sort Enabled RAID 6/60 Alternate Inconsistency Repair Policy Disabled Maximum Drive Request Queue Depth Automatic Monitor and Performance Analysis Delay 60 min
- Controller Configuration SummaryArrays 4 SmartCache Arrays 0 Logical Drives 4 Data Logical Drives 4 SmartCache for Logical Drives 0 Physical Drives 61 Data Drives 46 SmartCache Drives 0 Spare Drives 3 Drives in HBA Mode 0 Unassigned Drives 12 Primary Boot Logical Drive/Volume None Secondary Boot Logical Drive/Volume None
- Port SettingsPort 5I Port Location Internal Port 6I Port Location Internal Port 1E Port Location External Port 2E Port Location External Port 3E Port Location External Port 4E Port Location External
- Controller StatusController Status OK Cache Status OK Battery/Capacitor Status OK
- Storage EnclosuresDL18x25SFFD2600 SAS AJ832AStorageWorks D2600StorageWorks D2600
Each array is connected to its own port on the p812.
Array Details
- Status OK Used Space 20.0 TiB (100.0%) Total Usable Space 20.0 TiB Spare Drive Type Dedicated Spare Drives. Drives designated as spares can only be used as spare drives.
- Logical DrivesLogical Drive 3 18.19 TiB (20.00 TB)
- Physical Drives2 TB SAS HDD at Port 1E : Box 1 : Bay 22 TB SAS HDD at Port 1E : Box 1 : Bay 32 TB SAS HDD at Port 1E : Box 1 : Bay 42 TB SAS HDD at Port 1E : Box 1 : Bay 52 TB SAS HDD at Port 1E : Box 1 : Bay 62 TB SAS HDD at Port 1E : Box 1 : Bay 72 TB SAS HDD at Port 1E : Box 1 : Bay 82 TB SAS HDD at Port 1E : Box 1 : Bay 92 TB SAS HDD at Port 1E : Box 1 : Bay 102 TB SAS HDD at Port 1E : Box 1 : Bay 112 TB SAS HDD at Port 1E : Box 1 : Bay 12
- Spare Drives2 TB SAS HDD at Port 1E : Box 1 : Bay 1 (Spare)
- Array DetailsStatus OK Used Space 6146.0 GiB (100.0%) Total Usable Space 6.0 TiB Spare Drive Type Dedicated Spare Drives. Drives designated as spares can only be used as spare drives.
- Logical DrivesLogical Drive 5 5.73 TiB (6.30 TB)
- Physical Drives300 GB SAS HDD at Port 5I : Box 1 : Bay 3300 GB SAS HDD at Port 5I : Box 1 : Bay 4300 GB SAS HDD at Port 5I : Box 1 : Bay 5300 GB SAS HDD at Port 5I : Box 1 : Bay 6300 GB SAS HDD at Port 5I : Box 1 : Bay 7300 GB SAS HDD at Port 5I : Box 1 : Bay 8300 GB SAS HDD at Port 5I : Box 1 : Bay 9300 GB SAS HDD at Port 5I : Box 1 : Bay 10300 GB SAS HDD at Port 5I : Box 1 : Bay 11300 GB SAS HDD at Port 5I : Box 1 : Bay 12300 GB SAS HDD at Port 5I : Box 1 : Bay 13300 GB SAS HDD at Port 5I : Box 1 : Bay 14300 GB SAS HDD at Port 5I : Box 1 : Bay 15300 GB SAS HDD at Port 5I : Box 1 : Bay 16300 GB SAS HDD at Port 5I : Box 1 : Bay 17300 GB SAS HDD at Port 5I : Box 1 : Bay 18300 GB SAS HDD at Port 5I : Box 1 : Bay 19300 GB SAS HDD at Port 5I : Box 1 : Bay 20300 GB SAS HDD at Port 5I : Box 1 : Bay 21300 GB SAS HDD at Port 5I : Box 1 : Bay 22300 GB SAS HDD at Port 5I : Box 1 : Bay 23300 GB SAS HDD at Port 5I : Box 1 : Bay 24
- Spare Drives300 GB SAS HDD at Port 5I : Box 1 : Bay 25 (Spare)
- Device PathSmart Array P812 in Embedded Slot
HPE Smart Storage Administrator
- Array DetailsStatus OK Used Space 20.0 TiB (100.0%) Total Usable Space 20.0 TiB Spare Drive Type Dedicated Spare Drives. Drives designated as spares can only be used as spare drives.
- Logical DrivesLogical Drive 618.19 TiB (20.00 TB)
- Physical Drives2 TB SATA HDD at Port 2E : Box 1 : Bay 22 TB SATA HDD at Port 2E : Box 1 : Bay 32 TB SATA HDD at Port 2E : Box 1 : Bay 42 TB SATA HDD at Port 2E : Box 1 : Bay 52 TB SATA HDD at Port 2E : Box 1 : Bay 62 TB SATA HDD at Port 2E : Box 1 : Bay 72 TB SATA HDD at Port 2E : Box 1 : Bay 82 TB SATA HDD at Port 2E : Box 1 : Bay 92 TB SATA HDD at Port 2E : Box 1 : Bay 102 TB SATA HDD at Port 2E : Box 1 : Bay 112 TB SATA HDD at Port 2E : Box 1 : Bay 12
- Spare Drives2 TB SATA HDD at Port 4E : Box 1 : Bay 12 (Spare)
- Note: This is the array I want to remove. there are no logical drives.D2600 SAS AJ832A at Port 4E : Box 1SATA HDD 2 TB Bay 1SATA HDD 2 TB Bay 2SATA HDD 2 TB Bay 3SATA HDD 2 TB Bay 4SATA HDD 2 TB Bay 5SATA HDD 2 TB Bay 6SATA HDD 2 TB Bay 7SATA HDD 2 TB Bay 8SATA HDD 2 TB Bay 9SATA HDD 2 TB Bay 10SATA HDD 2 TB Bay 11