Re: C 7000 blade SFP incompatible

$
0
0

Hi,

 

  1. Determine which VC Ethernet Module in the enclosure is the "Standby" for Virtual Connect Manager (use VCSU �healthcheck).
  2. Power off the VC-Ethernet modules corresponding to the standby bay side of the enclosures (i.e., all even or all odd bays in the domain).
  3. Make a change to the configuration that affects all modules by selecting "Define Ethernet Network," then entering the Network Name as "Test-Delete." Do not add Uplinks - Select "Apply."
  4. Power on the VC-Ethernet modules powered off in step 2.
  5. Wait for modules to be recovered and checkpoint to be completed to Standby bay. Recovery time will vary depending on the size of the VC domain.
  6. Power off the VC-Ethernet modules corresponding to the primary bay side of the enclosures (i.e., all of the other VC-Ethernet modules).
  7. Reverse the change to the configuration (e.g., delete the network created in step 3).
  8. Power on the VC-Ethernet modules powered off in step 6.
  9. Wait for the modules to be recovered and checkpoint to be completed to standby bay. Recovery time will vary depending on the size of the VC domain.

 

I am an HPE Employee

If this information helps you with your issue, please click the thumb to register a Kudo.
Also, if it resolves your issue, please consider marking it as an Solution Accepted.