Hi,
- Determine which VC Ethernet Module in the enclosure is the "Standby" for Virtual Connect Manager (use VCSU �healthcheck).
- Power off the VC-Ethernet modules corresponding to the standby bay side of the enclosures (i.e., all even or all odd bays in the domain).
- Make a change to the configuration that affects all modules by selecting "Define Ethernet Network," then entering the Network Name as "Test-Delete." Do not add Uplinks - Select "Apply."
- Power on the VC-Ethernet modules powered off in step 2.
- Wait for modules to be recovered and checkpoint to be completed to Standby bay. Recovery time will vary depending on the size of the VC domain.
- Power off the VC-Ethernet modules corresponding to the primary bay side of the enclosures (i.e., all of the other VC-Ethernet modules).
- Reverse the change to the configuration (e.g., delete the network created in step 3).
- Power on the VC-Ethernet modules powered off in step 6.
- Wait for the modules to be recovered and checkpoint to be completed to standby bay. Recovery time will vary depending on the size of the VC domain.