Re: Replacement of MSA P2000 G3 Hp storage HDD

Can you please share the SMU screenshot of the error because as per the reply it sounds like you have mixed with you Vdisk and disks.

You must be having 1 vdisk made with 24 drives where 2 drives failed and vdisk now shows as offline.

Technically in RAID5 if two drives failed then there is no possibility of recovering the data.

However you can log a support case with HPE and they will try to recover the same. Otherwise you can contact me in private message with P2000 logs (not here in public forum) and I will try to recover as well.

 

Hope this helps!
Regards
Subhajit

If you feel this was helpful please click the KUDOS! thumb below!