Re: Replacement of MSA P2000 G3 Hp storage HDD

Need more details,

>> how many vdisks present in your system?

>> each vdisk made with how many drives ?

>> any of the vdisk shows as Offline or QTOF?

I am assuming if you have single vdisk made with 24 drives in RAID5 and now if two drives failed then this vdisk must be in Offline or QTOF state which is nothing but down situation for you.

If you have multiple RAID5 vdisk where only single drive failed but you don't have any spare drive configured then after insert of new disk you need to configure the same new drive as dedicated spare/Global spare.

 

Hope this helps!
Regards
Subhajit