Unhealthy Component
-------------------
Component ID: Enclosure 1, Current 12V Loc: lower-IOM B
Health: Degraded
Health Reason: The current sensor's status is unknown or its value is unexpected. It may be unhealthy.
Health Recommendation: - Check in the event log for events related to this component and follow the recommended actions for those events.Unhealthy Component
-------------------
Component ID: Enclosure 2, Expansion Module B, In Expansion Port
Health: Fault
Health Reason: The enclosure expansion port is inoperable.
Health Recommendation: - Check the SAS expansion cable between enclosures connected through the indicated port, and replace the cable if necessary.
- If this does not correct the problem, check that the modules at each end of the cable are powered up and have good health; replace any faulty controller module or expansion module.Unhealthy Component
-------------------
Component ID: Enclosure 1, Temperature Loc: lower-IOM B
Health: Degraded
Health Reason: The temperature sensor's status is unknown or its value is unexpected. It may be unhealthy.
Health Recommendation: - Check in the event log for events related to this component and follow the recommended actions for those events.Unhealthy Component
------------------- Component ID: Enclosure 1, Voltage 5V Loc: lower-IOM B
Health: Degraded
Health Reason: The voltage sensor's status is unknown or its value is unexpected. It may be unhealthy.
Health Recommendation: - Check in the event log for events related to this component and follow the recommended actions for those events.Unhealthy Component
-------------------
Component ID: Enclosure 1, Voltage 12V Loc: lower-IOM B
Health: Degraded
Health Reason: The voltage sensor's status is unknown or its value is unexpected. It may be unhealthy.
Health Recommendation: - Check in the event log for events related to this component and follow the recommended actions for those events.
↧
Re: P2000 G3 SAS ERROR ": The firmware version is not compatible, HP SPS-CHASSIS 2028"
↧